No account needed
The free matrix builder and the clash priority tool.
Clash matrix
A clash matrix holds your coordination standard for each pair of element classes: priority, owner, due days, tolerance and which element gives way. Wise drafts it, your team agrees it, and ClashWise applies it to every clash you publish from Navisworks.
Open the free matrix builderNorthbank · Level 026 classes · 5 disciplines
21 rules drafted · ready to reviewWise is drafting
| BeamsStructure | ColumnsStructure | DuctsMechanical | PipesPlumbing | Cable traysElectrical | SprinklersFire protection | |
|---|---|---|---|---|---|---|
| Beams | ||||||
| Columns | ||||||
| Ducts | ||||||
| Pipes | ||||||
| Cable trays | ||||||
| Sprinklers |
Wise · suggested
Ducts × Beams High
Rerouting the duct is cheaper than a beam penetration, which needs structural approval.
One rule, every clash
Edit the Ducts × Beams rule once. ClashWise analyses the clash sets that use the matrix again and updates each matched clash. Clashes your team edited by hand stay as they are.
Contacts in your organisation get one notification when new clashes reach them. The clash inspector shows the matched rule and can restore its values in one step.
Ducts × BeamsMechanical × Structure · rule 4 of 21
12 clashes in Ducts × Beams11 updated · 1 kept{count} updated
| # | Clash | Priority | Owner | Due |
|---|---|---|---|---|
| #038 | Supply duct SA-204 crosses beam B2-14 | ModerateHigh | —Priya Shah | —Oct 31 |
| #041 | Return duct RA-118 under beam B2-09 | ModerateHigh | —Priya Shah | —Oct 31 |
| #042 | Supply duct SA-206 through beam B2-15 | ModerateHigh | —Priya Shah | —Oct 31 |
| #047 | Exhaust duct EA-031 at beam B2-22 | ModerateHigh | —Priya Shah | —Nov 1 |
| #051 | Riser duct SA-R2 clips transfer beam TB-02Set by hand · kept | Critical | Dan Okafor | Oct 25 |
| #053 | Duct transition at beam B2-30 | ModerateHigh | —Priya Shah | —Nov 1 |
| #057 | Supply duct SA-211 through beam B2-31 | ModerateHigh | —Priya Shah | —Nov 2 |
| #063 | Return duct RA-120 flange at beam B2-07 | ModerateHigh | —Priya Shah | —Nov 2 |
| #066 | Fresh air duct OA-004 at edge beam EB-3 | ModerateHigh | —Priya Shah | —Nov 2 |
Showing 9 of 12 · Level 02, service zone
A rule covers one pair of classes within their disciplines, such as Ducts × Beams. Wise can suggest every value, and your team decides what stays.
Your own priority levels and colours. Start from Critical to Informational, add levels and set their order.
The status a matched clash starts in, chosen from your own list of statuses.
Hard or clearance, with a tolerance in millimetres, centimetres, metres, inches or feet.
The person or company that owns clashes for this pair.
The days allowed after a clash is first published. A date set by hand always wins.
Which element should move: element A, element B, either, or neither for an intended overlap or opening.
Tags for grouping and reporting, and notes the team can read beside the rule.
Switch a rule off to keep it in the matrix without applying it to clashes. Open a rule to read why Wise suggested its values.
Drafting a matrix by hand means deciding hundreds of pairs. Wise gives you a complete starting point to review.
Wise drafting is included with Pro and Business plans and their trials.
Rate a clash pair with the free toolSelect Beams × Ducts below. Change the test type or tolerance to see the proposed Navisworks test update, then switch to Clashes to browse the published results.
The illustrative matrix has four search sets, seven rules and 42 published clashes. Three representative clashes include model detail, including #042 in Beams × Ducts.
In Clashes, blue shading shows clash count, not urgency. A zero means a defined pair has no clashes in the current view, a dash means there is no rule, and unmapped clashes have their own entry so they remain part of the review.
You do not need Navisworks or a published clash set to build a matrix. When you are ready, the same rules prepare the Navisworks tests and receive the results.
Type, paste or import a class list from CSV or Excel, tick common classes or ask Wise for typical ones. Or generate from a published clash set, a new federation in Navisworks, a company standard or the free matrix builder.
See how many of a set's clashes would match a rule, and why the rest would not. Map model values such as Duct Fittings onto Ductwork, and model disciplines onto yours. Nothing changes until you save.
Each active rule becomes a clash test with its own test type and tolerance. See which sets and tests will be created, updated or left ready. Conflicting user edits are preserved.
Run the tests in Navisworks and publish. Every clash arrives matched to its rule, with the recommendations filled in.
Coordination Setup requires an active or trial Pro or Business organisation subscription. Navisworks performs the geometric checks. Already have search sets? The batch test tool creates pairwise tests from selected sets and is included with Starter.
Explore Navisworks automationThe matrix stays current as the project changes. After republishing, preview new class pairs and add the ones you need. Normal updates keep existing rules and edits, while exact synchronisation and regeneration are separate actions with their own review.
Clash cards show the matched rule, values that were overridden and rules that changed since assignment.
Ask Wise about the matrix or rate two selected elements against its rule. When Wise prepares a fix in Revit, it moves the element that gives way.
Export the rules workbook, edit supported fields and import the changes. Blank cells keep existing values.
Connect an AI client to read your matrices and preview rule edits before confirming them, with access your organisation controls.
Go through rules as a list, by pair or with split columns, or as a grid by discipline or class.
File a matrix in a project so its members can use and edit it. Business adds a company library of standards that every project can clone.
You can try the rating on a single pair for free: the clash priority tool rates two element types for priority, starting status and who gives way, on the web or from an AI client.
Open the clash priority toolThe free matrix builder and the clash priority tool.
Batch search sets and clash tests in Navisworks.
The matrix workspace: building and editing matrices, Wise drafting, analysis of published clashes, the fit check, Excel round trips and Coordination Setup.
A company library of standard matrices that every project can clone.
What you need to start, how it fits your models and what Wise changes.
No. You can build and edit a matrix from a list of classes. To apply it to clashes, publish clash results from Navisworks with the ClashWise plugin.
No. Navisworks detects the clashes. ClashWise manages them after they are published: it applies the matrix, tracks the work and records decisions.
Yes. Import its classes and disciplines from a CSV or Excel file, including a ClashWise rules workbook. Rule values can then be edited in the rules workbook and imported back.
Run the fit check against a published clash set and map the model's names onto your matrix classes. The mapping is saved on the matrix, so every clash set that uses it benefits.
Not unless you ask it to. Re-evaluate fills empty values by default, and replacing existing values is a separate choice for each field.
Up to 100 classes and 5,050 rules, which covers every pair of 100 classes, including each class with itself.
Start a trial with your own class list or a published clash set, or sketch your discipline pairs with the free matrix builder first.
Follow the full coordination workflow